IT Audit Factory — evidence-first audit & compliance operations
Free • Professional • MSP
Frameworks & Controls

ISO/IEC 27001

Identifiers and locally-authored audit guidance

All available frameworks

What the app checks

Technical checks run for the selected scope, available connectors and credentials. Results provide evidence for review; missing data is not a pass.

Explicit ControlRefs

Collector modules: ADCS, ADSEC, ASSETREC, BACKUP, CERTTLS, ENTRA, GPO, LINUX, NETWORK, SERVERS, STORAGE, VMWARE, VULN, WINDOWS.

Technical result still requires scope and assessor review. These module groups identify supporting scope; individual checks still need an explicit mapping.

Explicit requirement-to-test mappings

RequirementCollector / testWhat it checks or supports
A.5.9ADSEC / AD-COMPUTER-INVENTORY-001Supporting inventory evidence for A.5.9 — Inventory and ownership of information and related assets. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.5.9ASSETREC / ASSETREC-AD-001Supporting inventory evidence for A.5.9 — Inventory and ownership of information and related assets. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.5.9WINDOWS / WIN-INVENTORY-COVERAGE-001Supporting inventory evidence for A.5.9 — Inventory and ownership of information and related assets. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.2ADSEC / AD-PRIV-001Supporting access evidence for A.8.2 — Administration of privileged access rights. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.2ENTRA / ENTRA-ROLE-001Supporting access evidence for A.8.2 — Administration of privileged access rights. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.2ENTRA / ENTRA-GUEST-001Supporting access evidence for A.8.2 — Administration of privileged access rights. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.5ENTRA / ENTRA-MFA-REG-001Supporting mfa evidence for A.8.5 — Strong authentication appropriate to risk. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.9GPO / GPO-DETAIL-001Supporting config evidence for A.8.9 — Secure configuration baselines and change control. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.9WINDOWS / WIN-SMB1-001Supporting config evidence for A.8.9 — Secure configuration baselines and change control. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.20WINDOWS / WIN-FW-001Supporting boundary evidence for A.8.20 — Network security architecture and operation. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.8WINDOWS / WIN-PATCH-FRESHNESS-001Supporting patch evidence for A.8.8 — Identification and remediation of technical vulnerabilities. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.8VULN / VULN-IMPORT-001Supporting vulnerability evidence for A.8.8 — Identification and remediation of technical vulnerabilities. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.8VULN / VULN-HIGH-001Supporting vulnerability evidence for A.8.8 — Identification and remediation of technical vulnerabilities. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.8VULN / VULN-AGING-001Supporting vulnerability evidence for A.8.8 — Identification and remediation of technical vulnerabilities. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.7WINDOWS / WIN-AV-001Supporting malware evidence for A.8.7 — Prevention, detection and recovery from malware. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.24CERTTLS / CERTTLS-POSTURE-001Supporting transit evidence for A.8.24 — Use and lifecycle management of cryptography. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.24STORAGE / STOR-DATA-IN-FLIGHT-ENCRYPTION-001Supporting transit evidence for A.8.24 — Use and lifecycle management of cryptography. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.24STORAGE / STOR-AT-REST-ENCRYPTION-001Supporting rest evidence for A.8.24 — Use and lifecycle management of cryptography. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.13BACKUP / VEEAM-REPO-001Supporting backup evidence for A.8.13 — Resilient backup and verified restoration. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.8.17VMWARE / VMW-TIME-001Supporting time evidence for A.8.17 — Consistent time synchronization for reliable records. Verify asset/scope applicability and review the exact result; this does not establish the full requirement.
A.5.16ADSEC / AD-PREFLIGHT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-PREFLIGHT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2ADSEC / AD-PREFLIGHT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17ADSEC / AD-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADSEC / AD-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ADSEC / AD-LIFECYCLE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-LIFECYCLE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-PRIV-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ADSEC / AD-DC-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16ADSEC / AD-DC-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9GPO / GPO-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17GPO / GPO-PASSWORD-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5GPO / GPO-PASSWORD-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-OS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-OS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-OS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21WINDOWS / WIN-FW-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-SMB1-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20WINDOWS / WIN-SMB1-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16WINDOWS / WIN-AV-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-RDP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-RDP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / VEEAM-JOB-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / VEEAM-JOB-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.23ENTRA / ENTRA-CONTEXT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ENTRA / ENTRA-CONTEXT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ENTRA / ENTRA-ROLE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8VMWARE / VMW-HOST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9VMWARE / VMW-HOST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20VMWARE / VMW-HOST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9VMWARE / VMW-VM-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.12STORAGE / STOR-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13STORAGE / STOR-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20STORAGE / STOR-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24STORAGE / STOR-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-PATCH-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-PATCH-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-PATCH-COHORT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-PATCH-COHORT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1LINUX / LNX-OS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8LINUX / LNX-OS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9LINUX / LNX-OS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8LINUX / LNX-PATCH-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9LINUX / LNX-PATCH-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-VENDOR-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-VENDOR-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-MGMT-TLS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24NETWORK / NET-MGMT-TLS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-MGMT-SSH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24NETWORK / NET-MGMT-SSH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17NETWORK / NET-MERAKI-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-MERAKI-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-MERAKI-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-SCOPE-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-SCOPE-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-DEVICE-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-DEVICE-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-MGMT-PREFLIGHT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-MGMT-PREFLIGHT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1NETWORK / NET-MERAKI-ORG-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-MERAKI-ORG-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-MERAKI-ORG-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.33NETWORK / NET-EVIDENCE-COVERAGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9NETWORK / NET-EVIDENCE-COVERAGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1NETWORK / NET-OBJ-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9NETWORK / NET-OBJ-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8NETWORK / NET-OBJ-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9NETWORK / NET-OBJ-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-003Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24NETWORK / NET-OBJ-003Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8NETWORK / NET-OBJ-004Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-004Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24NETWORK / NET-OBJ-004Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15NETWORK / NET-OBJ-005Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18NETWORK / NET-OBJ-005Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2NETWORK / NET-OBJ-005Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16NETWORK / NET-OBJ-006Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17NETWORK / NET-OBJ-006Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5NETWORK / NET-OBJ-006Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-007Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-OBJ-007Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.15NETWORK / NET-OBJ-008Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16NETWORK / NET-OBJ-008Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.15NETWORK / NET-OBJ-009Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16NETWORK / NET-OBJ-009Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.17NETWORK / NET-OBJ-010Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-011Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-OBJ-011Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16NETWORK / NET-OBJ-012Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-012Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-013Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.22NETWORK / NET-OBJ-013Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-014Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-OBJ-014Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-015Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-OBJ-015Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.22NETWORK / NET-OBJ-015Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-016Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24NETWORK / NET-OBJ-016Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-017Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24NETWORK / NET-OBJ-017Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24NETWORK / NET-OBJ-018Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30NETWORK / NET-OBJ-019Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.14NETWORK / NET-OBJ-019Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13NETWORK / NET-OBJ-020Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9NETWORK / NET-OBJ-020Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.7NETWORK / NET-OBJ-021Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16NETWORK / NET-OBJ-021Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-021Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.7NETWORK / NET-OBJ-022Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-022Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.15NETWORK / NET-OBJ-023Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.32NETWORK / NET-OBJ-023Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-024Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21NETWORK / NET-OBJ-024Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8NETWORK / NET-OBJ-025Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9NETWORK / NET-OBJ-025Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.14NETWORK / NET-OBJ-026Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-026Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.31NETWORK / NET-OBJ-027Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24NETWORK / NET-OBJ-027Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16NETWORK / NET-OBJ-028Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18NETWORK / NET-OBJ-028Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2NETWORK / NET-OBJ-028Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15NETWORK / NET-OBJ-029Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20NETWORK / NET-OBJ-029Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.33NETWORK / NET-OBJ-030Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9NETWORK / NET-OBJ-030Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.33NETWORK / NET-CLI-RAW-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9NETWORK / NET-CLI-RAW-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.15NETWORK / NET-CLI-RAW-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-INVENTORY-COVERAGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-INVENTORY-COVERAGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9WINDOWS / WIN-ROLE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-ROLE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9WINDOWS / WIN-SERVICE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-SERVICE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16WINDOWS / WIN-SERVICE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15WINDOWS / WIN-LOCAL-ACCOUNT-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16WINDOWS / WIN-LOCAL-ACCOUNT-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18WINDOWS / WIN-LOCAL-ACCOUNT-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2WINDOWS / WIN-LOCAL-ACCOUNT-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9WINDOWS / WIN-SHARE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.3WINDOWS / WIN-SHARE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20WINDOWS / WIN-SHARE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9WINDOWS / WIN-STORAGE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-STORAGE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.10WINDOWS / WIN-STORAGE-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9WINDOWS / WIN-NETWORK-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20WINDOWS / WIN-NETWORK-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21WINDOWS / WIN-NETWORK-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9WINDOWS / WIN-REMOTE-AUDIT-ACCESS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-REMOTE-AUDIT-ACCESS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-REMOTE-AUDIT-ACCESS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ADSEC / AD-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8ADSEC / AD-DC-MAINTENANCE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ADSEC / AD-DC-MAINTENANCE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.14ADSEC / AD-DC-MAINTENANCE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ADSEC / AD-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17ADSEC / AD-PASSWORD-NOT-REQUIRED-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADSEC / AD-PASSWORD-NOT-REQUIRED-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17ADSEC / AD-KERBEROS-PREAUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADSEC / AD-KERBEROS-PREAUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15ADSEC / AD-DELEGATION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-DELEGATION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2ADSEC / AD-DELEGATION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADSEC / AD-DELEGATION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24ADSEC / AD-KERBEROS-DES-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADSEC / AD-KERBEROS-DES-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17ADSEC / AD-PRIV-PASSWORD-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-PRIV-PASSWORD-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2ADSEC / AD-PRIV-PASSWORD-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15ADSEC / AD-MACHINE-ACCOUNT-QUOTA-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-MACHINE-ACCOUNT-QUOTA-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ADSEC / AD-MACHINE-ACCOUNT-QUOTA-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17ADSEC / AD-KRBTGT-AGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADSEC / AD-KRBTGT-AGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ADSEC / AD-KRBTGT-AGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17ADSEC / AD-PASSWORD-POLICY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADSEC / AD-PASSWORD-POLICY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15ADSEC / AD-TRUST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-TRUST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20ADSEC / AD-TRUST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1ADSEC / AD-COMPUTER-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ADSEC / AD-COMPUTER-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.14ADSEC / AD-REPLICATION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16ADSEC / AD-REPLICATION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ADSEC / AD-REPLICATION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ADSEC / AD-ADVANCED-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADSEC / AD-ADVANCED-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADSEC / AD-ADVANCED-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24ADCS / ADCS-PREFLIGHT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADCS / ADCS-PREFLIGHT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24ADCS / ADCS-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9ADCS / ADCS-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ADCS / ADCS-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24ADCS / ADCS-TEMPLATE-RISK-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15ADCS / ADCS-TEMPLATE-RISK-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ADCS / ADCS-TEMPLATE-RISK-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADCS / ADCS-TEMPLATE-RISK-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24ADCS / ADCS-CA-CERT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ADCS / ADCS-CA-CERT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24ADCS / ADCS-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ADCS / ADCS-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1ASSETREC / ASSETREC-AD-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9ASSETREC / ASSETREC-BACKUP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13ASSETREC / ASSETREC-BACKUP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30ASSETREC / ASSETREC-BACKUP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9ASSETREC / ASSETREC-COVERAGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13ASSETREC / ASSETREC-COVERAGE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / BACKUP-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / BACKUP-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / VEEAM-PROTECTED-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9BACKUP / VEEAM-PROTECTED-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / VEEAM-PROTECTED-INVENTORY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / VEEAM-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / VEEAM-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / VEEAM-REST-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / VEEAM-REST-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17BACKUP / VEEAM-REST-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / VEEAM-REST-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / VEEAM-REST-JOB-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / VEEAM-REST-JOB-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / VEEAM-REST-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / VEEAM-REST-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / BACKUP-MGMT-ENDPOINT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / BACKUP-MGMT-ENDPOINT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / BACKUP-MGMT-TARGET-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / BACKUP-MGMT-TARGET-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13BACKUP / BACKUP-DEEP-ADAPTER-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.30BACKUP / BACKUP-DEEP-ADAPTER-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24CERTTLS / CERTTLS-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20CERTTLS / CERTTLS-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21CERTTLS / CERTTLS-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24CERTTLS / CERTTLS-CONNECT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20CERTTLS / CERTTLS-CONNECT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21CERTTLS / CERTTLS-CONNECT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20CERTTLS / CERTTLS-POSTURE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21CERTTLS / CERTTLS-POSTURE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15ENTRA / ENTRA-GUEST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ENTRA / ENTRA-GUEST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ENTRA / ENTRA-GUEST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17ENTRA / ENTRA-APP-CREDENTIAL-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ENTRA / ENTRA-APP-CREDENTIAL-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ENTRA / ENTRA-APP-CREDENTIAL-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15ENTRA / ENTRA-CA-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ENTRA / ENTRA-CA-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ENTRA / ENTRA-CA-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17ENTRA / ENTRA-MFA-REG-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9ENTRA / INTUNE-DEVICE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1ENTRA / INTUNE-DEVICE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24ENTRA / INTUNE-DEVICE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8ENTRA / INTUNE-DEVICE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1ENTRA / INTUNE-COMPLIANCE-POLICY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9ENTRA / INTUNE-COMPLIANCE-POLICY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.7ENTRA / DEFENDER-SECURE-SCORE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8ENTRA / DEFENDER-SECURE-SCORE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.16ENTRA / DEFENDER-SECURE-SCORE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.23ENTRA / ENTRA-GRAPH-DEPENDENCY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ENTRA / ENTRA-GRAPH-DEPENDENCY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2ENTRA / ENTRA-GRAPH-DEPENDENCY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ENTRA / ENTRA-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ENTRA / ENTRA-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ENTRA / ENTRA-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ENTRA / ENTRA-AUTH-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18ENTRA / ENTRA-AUTH-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ENTRA / ENTRA-AUTH-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.23ENTRA / ENTRA-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ENTRA / ENTRA-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2ENTRA / ENTRA-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9GPO / GPO-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1LINUX / LNX-SSH-DEPENDENCY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9LINUX / LNX-SSH-DEPENDENCY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17LINUX / LNX-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5LINUX / LNX-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9LINUX / LNX-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17LINUX / LNX-SSH-KEY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5LINUX / LNX-SSH-KEY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.12STORAGE / STOR-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13STORAGE / STOR-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24STORAGE / STOR-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9STORAGE / STOR-PROFILE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1STORAGE / STOR-PROFILE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17STORAGE / STOR-CONNECTION-POLICY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24STORAGE / STOR-CONNECTION-POLICY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20STORAGE / STOR-MGMT-TRANSIT-ENCRYPTION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21STORAGE / STOR-MGMT-TRANSIT-ENCRYPTION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24STORAGE / STOR-MGMT-TRANSIT-ENCRYPTION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17STORAGE / STOR-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9STORAGE / STOR-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.12STORAGE / STOR-AT-REST-ENCRYPTION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.13STORAGE / STOR-AT-REST-ENCRYPTION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20STORAGE / STOR-DATA-IN-FLIGHT-ENCRYPTION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.21STORAGE / STOR-DATA-IN-FLIGHT-ENCRYPTION-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9STORAGE / STOR-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1STORAGE / STOR-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9VMWARE / VMW-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20VMWARE / VMW-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9VMWARE / VMW-POWERCLI-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20VMWARE / VMW-POWERCLI-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20VMWARE / VMW-TLS-TRUST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.24VMWARE / VMW-TLS-TRUST-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9VMWARE / VMW-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.20VMWARE / VMW-COLLECT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9VULN / VULN-IMPORT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9VULN / VULN-HIGH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8VULN / VULN-IMPORT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.9VULN / VULN-IMPORT-ERRORExisting ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17WINDOWS / WIN-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-PATCH-FRESHNESS-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-REBOOT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-REBOOT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.14WINDOWS / WIN-REBOOT-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-PATCH-REBOOT-SUMMARY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-PATCH-REBOOT-SUMMARY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.14WINDOWS / WIN-PATCH-REBOOT-SUMMARY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15WINDOWS / WIN-DOMAIN-MEMBERSHIP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16WINDOWS / WIN-DOMAIN-MEMBERSHIP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.18WINDOWS / WIN-DOMAIN-MEMBERSHIP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-DOMAIN-MEMBERSHIP-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.6WINDOWS / WIN-DISK-CAPACITY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.14WINDOWS / WIN-DISK-CAPACITY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-SCOPE-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.15WINDOWS / WIN-CRED-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.17WINDOWS / WIN-CRED-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-CRED-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-DISCOVERY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.8WINDOWS / WIN-DISCOVERY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-DISCOVERY-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.1WINDOWS / WIN-SCOPE-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.9WINDOWS / WIN-SCOPE-002Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.23ENTRA / CLOUD-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.5.16ENTRA / CLOUD-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.2ENTRA / CLOUD-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.
A.8.5ENTRA / CLOUD-AUTH-001Existing ISO collector control reference retained as supporting evidence. Scope, applicability and full control implementation require independent review.

What requires manual review

Confirm scope and applicability, review the requirement guidance, collect policies and records, conduct interviews or observations where needed, and assess evidence relevance and freshness. Record owners, rationale, workpaper conclusions and remediation. An assessor makes the final decision; a technical pass does not approve the whole framework.

ISO control titles/text require an appropriately licensed copy.

Where it is available

This preparation framework is listed in the C32 Professional/MSP application catalog. Free retains its ISO assessment limits. Availability of a framework is separate from the extent of automated scanning.

Coverage shown here comes from the application’s C32 requirement and mapping catalogs.